BSTFLEX PTFE Composite Flange Spray Shields fit around flanged pipe connections to help limit direct spray from a leaking joint. Choose a rectangular wrap-style body or a round cover, with an optional PFA viewing section for visual inspection. The cover size, drawcords and closing arrangement are specified for the flange geometry and service conditions. Send your flange schedule, fluid details, temperature and installation photographs for a quotation.
  • order(moq):

    1
Product Detail

PTFE Composite Flange Guards in Two Cover Styles

BSTFLEX PTFE Composite Flange Spray Shields fit around assembled pipe flanges to help limit direct spray from a leaking joint. The flexible body is made from PTFE composite fabric. Rectangular wrap-style and round configurations are available, with an optional PFA viewing section for visual inspection of the covered area.

Choose the cover style around the actual installation: the flange diameter, the width across the joint and bolts, the space beside the pipe, and the position from which the joint will be inspected.


Wrap-Style and Round Configurations

Rectangular Wrap-Style Body

The rectangular version wraps around the flange assembly, with drawcords gathering the side edges towards the pipe and a central closure securing the body. “Rectangular” describes the cover style; the installed guard surrounds a circular pipe flange.

This construction needs enough width to cover the joint and its projecting fasteners. When requesting a cover, show where the closure can be reached and identify nearby supports or equipment that could obstruct it. A clear viewing section can be requested with the construction.

Round Cover Body

The round version has a defined circular profile around the flange, with pipe openings at the sides. The illustrated configurations show bound edges, stitched sections and drawcords, with a transparent section around the joint area.

Specify the flange outside diameter, pipe outside diameter and assembled connection width together. These dimensions determine the required body size and side openings. Brown and gray examples are shown; include any color preference with the requested construction.


Viewing Window and Closure Position

A PFA viewing window can be added where routine inspections require a view of the joint without opening the cover. An opaque configuration can also be specified. For a windowed cover, send a photograph showing the normal inspection direction so the viewing area and closure position can be considered together.

The window should remain visible after installation. A pipe support, insulation jacket or adjacent connection may obstruct the viewing area even when the shield fits the flange itself. Include these details in the enquiry.

Drawcord options include PTFE and polypropylene. Cord material and the closing arrangement are selected with the cover style and service conditions. Include any restrictions on seams, edge binding or closure materials when purchasing PTFE fabric flange guards for a specified project.


Measure the Installed Joint

A nominal pipe size is only part of the information needed for fabric flange spray shields. Use a dimensioned sketch or flange schedule to record the following measurements.

  1. Flange outside diameter: measure or identify the outside diameter of the assembled flange pair.
  2. Assembled connection width: record the flange-pair width, with bolt and stud projections shown separately.
  3. Pipe outside diameter: provide the diameter at each side where the cover opening will sit.
  4. Available space: show the distance to supports, valve bodies, adjacent joints and insulation, together with access to the proposed closure.

Add the flange standard, nominal size and pressure class or designation. Reference sizing follows HG/T 20592 flange dimensions. For ASME, EN, DIN, JIS or another standard, provide the exact designation and relevant dimensions for review.


Match the Construction to the Process

When specifying chemical spray shields, provide the process liquid, concentration, normal temperature and any maximum or cleaning temperature. If the line handles different fluids between batches, list each duty. Cleaning chemicals and exposure around the outside of the pipe may also affect component selection.

The selected composite body, window, cords, seams and closure must be assessed together. Include operating pressure for the application review; the pressure class of the flange is not a tested pressure rating for the cover. Any temperature or chemical compatibility requirement should refer to the complete ordered construction.


Removal and Inspection During Maintenance

The removable cover provides access for planned flange maintenance. Follow the site's isolation and decontamination procedure before fitting, opening or removing a shield. Use the installation instructions supplied for the ordered construction, as closure details depend on the selected construction.

Before refitting, check the fabric, seams, bound edges and cords for wear or damage. Inspect the viewing section, where fitted, for cracking, clouding or contamination that prevents a clear view. Confirm that the closure and pipe openings still fit after changes to bolts, insulation or nearby pipework.


Common Selection Questions

How do PTFE composite and pure PTFE shields differ?

The distinction is the body material. This product uses PTFE composite fabric; our Pure PTFE Flange Spray Shields use pure PTFE body material. Specify any restrictions on composite materials and other components when requesting either version. Compare the proposed constructions against the same service conditions.

Does the viewing window automatically detect a leak?

The PFA section provides visual access during inspection. It is not an automatic leak sensor. The window needs to remain visible and clean enough for the site's routine checks.

Can a flange spray shield repair a leaking gasket?

No. The shield is an external spray-protection cover. It does not reseal the flange, retain process pressure or replace the repair of a leaking connection.


Custom PTFE Flange Guards: Quotation Information

For an installation with several flange sizes, send one schedule with a separate line for each size and construction. Include the preferred wrap-style or round body, window requirement, service conditions and quantity. Add drawings or photographs for joints with restricted access.

Send an enquiry to BSTFLEX or email sales@pkfiresleeve.com. For other cover materials and component types, browse our Flange & Valve Protection Covers.

Send A Message

If you have questions or suggestions, please leave us a message,we will reply you as soon as we can!

related products
Stainless Steel Band-Type Flange Guards
BSTFLEX Stainless Steel Band-Type Flange Guards are removable metal covers fitted around the outer perimeter of industrial flanged connections. The open-sided construction features a formed stainless steel band, edge tabs and a latch closure for removal during planned maintenance. Guard diameter and band width are selected to match the flange assembly and available clearance. Material grade and application requirements are confirmed during quotation. Reference sizing follows HG/T 20592 flange dimensions, while requests for other flange standards are reviewed against customer drawings. Send your flange dimensions, operating conditions and quantity for a project-specific quotation.
Multi-Layer Stainless Steel Mesh Flange Guards
BSTFLEX Multi-Layer Stainless Steel Mesh Flange Guards combine an external metal band with an internal layered mesh insert for spray-protection requirements at industrial flanged connections. The mesh is positioned around the joint to interrupt a concentrated leak jet, while the removable closure provides access during planned maintenance. Guard dimensions, stainless steel grade and mesh construction are specified against the flange geometry and service conditions. Send your flange standard, dimensions, process medium, operating temperature, pressure and quantity for a project quotation. Protective performance and any required testing must be confirmed for the complete assembly.
Stainless Steel Flange Guards
BSTFLEX Stainless Steel Flange Guards are removable metal protection covers designed for industrial flanged connections. The full-cover construction includes a cylindrical stainless steel body, annular side panels around the pipe openings, a hinged opening section and stainless steel latch closure for installation and maintenance access. Guards are custom sized to suit the flange outside diameter, assembled width, pipe diameter and surrounding clearance. Standard reference sizing can be based on HG/T 20592 dimensions, while other flange standards can be reviewed from customer drawings or measured dimensions.
PVC Flange Spray Shields
BSTFLEX PVC Flange Spray Shields are flexible covers for external spray protection around bolted flange connections. The range includes clear PVC, translucent PVC mesh fabric, and clear PVC combined with polypropylene fabric side sections. Transparent areas allow the covered connection to be viewed during routine inspection. The mesh-fabric version uses polypropylene drawcords and a hook-and-loop closure. Specify the flange dimensions, fluid, concentration, temperature and quantity to select the construction and fit for your installation.
Pure PTFE Flange Spray Shields
BSTFLEX Pure PTFE Flange Spray Shields are removable covers designed to help limit direct liquid spray from flanged pipe joints. The round design uses pure PTFE body material and can be specified with a PFA viewing window for routine visual checks. PTFE or polypropylene drawcords are selected to suit the service conditions. Send the flange dimensions, process fluid, concentration and operating temperature to specify the cover and its components for your installation.
PP Flange Spray Shields
BSTFLEX PP Flange Spray Shields use a flexible polypropylene fabric body to help limit direct liquid spray from bolted flange connections. The removable cover has pipe openings and drawcords, with dimensions specified around the installed joint. Send your flange dimensions, process conditions, maintenance access requirements and quantities to select the cover construction and request a quotation.
PP Plastic Flange Guards
BSTFLEX PP Plastic Flange Guards are rigid polypropylene covers for external spray protection around assembled pipe flanges. The shell and pipe openings are selected to suit the flange diameter, bolt projections and connection width. Product examples are shown in yellow, blue and red. Send flange drawings, installation clearances, operating conditions and quantities to confirm the required configuration.
Valve Spray Shields
BSTFLEX Valve Spray Shields are fitted covers designed to help limit direct liquid spray from selected valve body joints and pipe connections. PTFE, PVC and polypropylene constructions are selected for the process fluid and installation. Ball valve and butterfly valve designs are available, while gate, globe, check, diaphragm, plug and other valve layouts are reviewed for sectional covers. Send valve drawings, operating conditions and photographs to confirm material, coverage and operating clearance.
leave a message

leave a message

    If you have questions or suggestions, please leave us a message,we will reply you as soon as we can!

Home

Products

About

Contact/RFQ

top