order(moq):
1BSTFLEX Pure PTFE Flange Spray Shields are removable covers fitted around flanged pipe joints to help limit direct liquid spray if a gasket leaks. The round cover uses pure PTFE body material, with openings around the adjoining pipe. A PFA viewing window can be specified for installations where the joint needs to remain visible during routine inspections.
These PTFE safety spray shields provide an external barrier around the joint. They do not seal the flange or replace gasket maintenance.

The cover body, drawcords and inspection window have different jobs. Specify each component to match the process conditions and the site's material requirements.
| Component | Configuration | Information to include in your enquiry |
|---|---|---|
| Cover body | Pure PTFE material in a round flange-cover configuration | Flange dimensions, process fluid and any project material restrictions |
| Inspection window | Optional transparent PFA section | Whether visual access is required and the available viewing position |
| Drawcords | PTFE or polypropylene, selected for the specified service | Required cord material, chemical exposure and temperature |
| Seams and closures | Details agreed with the selected construction | Any restrictions on materials used throughout the assembly |
In this product name, “pure PTFE” identifies the body material. If a PFA window or polypropylene cords are selected, those components are identified separately in the order specification.
The optional PFA viewing section allows the covered joint area to be checked without removing the shield. This can be useful on lines inspected regularly for visible liquid, staining or residue. Choose the window position with the installed pipe orientation and nearby equipment in mind.
A cover without the viewing window can also be specified. Where a window is included, keep it accessible for inspection and cleaning under the site's maintenance procedure.
For chemical flange guards, start with the actual liquid handled by the line. A chemical name alone may leave out the concentration, mixed constituents or temperature needed to assess the complete cover. For batch processes, include changes in duty between production and cleaning.
The line pressure supplied for a technical review is not a pressure rating for the shield.
For a batch order, group the joints by flange size, standard and installation details. Two joints with the same nominal pipe size may need different covers if their flange dimensions, bolts or available clearance differ.
| Order detail | What to send |
|---|---|
| Flange identification | Standard, nominal size and flange pressure class or designation |
| Outside dimensions | Flange outside diameter and pipe outside diameter |
| Assembled connection width | Flange-pair width, with bolt and stud projections shown separately |
| Installation space | Clearance to supports, adjacent joints, valve bodies and insulation |
| Material options | Window requirement, drawcord material and any component restrictions |
| Project quantities | Quantity for each size, flange schedule or drawing, and installation photographs |
Reference sizing follows HG/T 20592 flange dimensions. For ASME, EN, DIN, JIS or another standard, identify the exact designation and send the relevant dimensions for review. Nominal size alone should not be used to confirm a fit.
Follow the site's isolation and decontamination procedure before fitting or opening a cover. Check that the cover matches the flange pair and that nearby bolts or supports will not damage it. Position the viewing section, where specified, so it can be seen from the normal inspection point. Secure the cover according to the instructions supplied with the selected construction.
The removable construction allows access during planned flange maintenance. Before reuse, inspect the body, cords, seams and window for damage, contamination or loss of visibility.
The distinction is the specified body material. This product uses pure PTFE body material; a PTFE composite cover combines PTFE with other materials. Where a project restricts particular substrates or components, include those requirements when requesting a quotation.
The operating range depends on the complete construction and the service conditions. Send the normal and maximum temperatures with the fluid details. A temperature range for the PTFE material alone should not be used as the rating of a finished shield with different window or cord options.
Compare the fluid, concentration, temperature and component requirements for the actual installation. Our PVC Flange Spray Shields are a separate material option. Share the same service information when requesting a comparison so the proposed constructions can be assessed on a consistent basis.
Send BSTFLEX your flange schedule or dimensions, process conditions, preferred window and cord options, and quantity for each size. Include a photograph or drawing where space around the flange is restricted.
Request a quotation or email sales@pkfiresleeve.com. You can also view the Flange & Valve Protection Covers range for other materials and constructions.
Previous:
PVC Flange Spray ShieldsNext:
PTFE Composite Flange Spray ShieldsIf you have questions or suggestions, please leave us a message,we will reply you as soon as we can!