1BSTFLEX PVC flange spray shields are flexible covers fitted around bolted flange connections. They are intended to help limit direct liquid spray from a leaking joint by placing an external barrier around the connection. The range includes clear PVC, translucent PVC mesh fabric, and clear PVC combined with polypropylene fabric side sections.
Choose the construction according to the fluid, operating conditions and access needed for inspection. Clear areas provide a view of the covered connection, while the removable design allows access during planned maintenance. These products form part of our Flange & Valve Protection Covers range.

| Configuration | Construction | Viewing Area |
|---|---|---|
| Clear PVC Flange Guards | Clear PVC body with bound edges and drawcords. | The clear body allows the covered area to be viewed without first removing the shield. |
| PVC Mesh Fabric Shields | Translucent PVC fabric with a visible grid pattern. The mesh-fabric configuration uses polypropylene drawcords and a hook-and-loop closure. | The translucent body provides a more restricted view than clear PVC. |
| PVC with Polypropylene Fabric | A clear PVC viewing section combined with polypropylene fabric side sections. | The transparent section provides a view of the connection; the fabric sections are opaque. |
The three configurations have different body constructions. Specify whether you need a fully clear cover, a translucent grid fabric or a clear viewing section with fabric sides. For the combined design, show which part of the connection needs to remain visible.
The mesh-fabric PVC flange guard wraps around the connection and closes with a hook-and-loop fastening. Polypropylene drawcords gather the openings on either side of the flange assembly. The closure can be released when the cover needs to be removed for inspection or maintenance.
The cover width, overlap and side openings need to suit the installed flange. A cover pulled across projecting studs or nearby fittings may not sit as intended. Include those details in the dimension sketch so the fastening arrangement can be matched to the available space.

Nominal pipe size alone is not enough to specify a PVC flange cover. Provide the flange standard and size, then check the outside dimensions of the assembled connection. Include any spacer, adapter or instrument connection between the mating flanges.
A front photograph and a side photograph help explain the measurements. For several connections, use a flange schedule with a location or tag number for each size. If dimensions are incomplete, send the drawing and photographs first and identify the measurements still needed.
Material selection starts with the liquid and its concentration. Include normal and maximum operating temperatures, operating pressure with units, and any cleaning fluid that could contact the cover. Also identify nearby hot surfaces and whether the installation is indoors or outdoors.
Clear PVC film, PVC mesh fabric and PVC combined with polypropylene fabric should not be assumed to have identical service limits. The selected body material, drawcords and closure need to suit the same application. A flange pressure class describes the piping connection; it is not a pressure rating for the external shield.
Safety spray shields do not seal a failed joint. The flange gasket and bolting remain responsible for sealing the connection, and a leak requires the appropriate maintenance response. State any required spray-protection test or acceptance criterion with the inquiry.
Clear PVC gives maintenance personnel a view of the covered area during routine checks. Position the viewing area where it can be seen from the normal inspection route. Dirt, deposits or damage can reduce visibility, so the condition of the transparent material matters as well as its position.
Fit or remove the shield only after the connection has been made safe under the site's work procedures. Follow the instructions for the selected configuration and keep any specified drainage or inspection provisions unobstructed. Do not approach an active leak to fit or adjust a cover.
During planned maintenance, check the PVC, fabric sections, edge bindings, cords and closure for tears, cracking, stiffness or chemical damage. Assess the condition of the complete cover before returning it to service.
No. The transparent material provides a viewing area for manual inspection. It is not an automatic sensor or a chemical indicator. If the project requires a separate leak-detection function, include that requirement in the specification.
Send the normal and maximum temperatures together with the fluid and concentration. The assessment needs to cover the PVC body, drawcords and closure as one assembly.
A flange shield covers a flanged connection. Covering the valve body also requires allowance for its shape, handle or actuator. Send a separate valve drawing when the required coverage extends beyond the flange.
The PVC designs described here are for external spray protection and do not contain a thermal insulation core. Specify heat retention or surface-temperature control separately when those functions are required.
Send BSTFLEX the flange standard, nominal size, measured dimensions and required quantity. Add the fluid and concentration, operating temperature and pressure, and your preferred PVC construction. For a clear cover, identify the area that needs to remain visible.
For a project with several sizes, attach a flange schedule and installation photographs. Include your required delivery date and any material documentation or inspection requirements so they can be addressed in the quotation.
Request a quotation for PVC flange spray shields or send your drawings and photographs to sales@pkfiresleeve.com.