Anhui Parker New Material Co.,Ltd
ISO9001      IATF16949

insulation blanket manufacturer
Products

Stainless Steel Band-Type Flange Guards

BSTFLEX Stainless Steel Band-Type Flange Guards are removable metal covers fitted around the outer perimeter of industrial flanged connections. The open-sided construction features a formed stainless steel band, edge tabs and a latch closure for removal during planned maintenance. Guard diameter and band width are selected to match the flange assembly and available clearance. Material grade and application requirements are confirmed during quotation. Reference sizing follows HG/T 20592 flange dimensions, while requests for other flange standards are reviewed against customer drawings. Send your flange dimensions, operating conditions and quantity for a project-specific quotation.
  • order(moq):

    1
Product Detail


Stainless Steel Band-Type Flange Guards for Industrial Connections

BSTFLEX Stainless Steel Band-Type Flange Guards are removable metal covers that fit around the outer perimeter of a bolted flange connection. The open-sided band construction provides an alternative to a full-enclosure housing with annular side panels. A stainless steel latch secures the band and allows it to be opened for removal during scheduled inspection and maintenance.

The illustrated design features a formed stainless steel body, edge tabs and a latch closure. Each inquiry is reviewed against the flange dimensions, installation clearance, material requirements and intended protective function.

Part of our Flange & Valve Protection Covers range, these band-type guards are specified by connection geometry rather than nominal pipe size alone.


Open-Sided Construction with a Removable Latch Closure

Metal Band Around the Flange Perimeter

The curved band surrounds the outside of the flange assembly. Unlike a full-enclosure flange cover, this design does not include annular end panels around the pipe openings. Band diameter and width define the area covered, so both dimensions must suit the actual connection.

Formed Edge Details

The reference design includes formed tabs along the band edges. The final tab arrangement and surrounding clearance should be checked against the flange profile, bolt positions and installation drawing.

Access for Planned Maintenance

The latch can be released to open and remove the cover when the connection has been made safe for inspection. The guard is fitted externally; it is not inserted between flange faces and does not replace the gasket or flange bolting.


Construction and Ordering Specifications

Item Specification or Ordering Requirement
Product Type Stainless steel band-type flange guard
Brand BSTFLEX
Body Construction Formed stainless steel band with open sides
Material Grade Required stainless steel grade to be specified in the inquiry and confirmed in the quotation
Closure Stainless steel latch; component material requirements to be confirmed with the order
Edge Configuration Formed tabs as shown in the reference design; final arrangement according to the agreed drawing
Installation Position External fit around the flange assembly
Principal Dimensions Band diameter, band width and clearance around the assembled connection
Reference Flange Standard HG/T 20592 flange dimensions; identify the size and pressure designation when ordering
Other Flange Standards Submit the applicable standard and dimensional drawing for review
Application Information Process medium, operating temperature, operating pressure and required protective function


Specify the Material for the Complete Assembly

Identify the stainless steel grade required by your project when requesting a quotation. Requirements for the band body, latch and any additional components should be stated together so that the complete assembly can be reviewed against the purchasing specification.

Requests for a particular grade, including 316 stainless steel, require written confirmation before ordering. Surface appearance alone should not be used to identify the material. Include any material documentation or traceability requirements with the initial inquiry.


How to Specify the Correct Flange Band Size

A nominal pipe size does not fully describe the outside dimensions of a bolted flange assembly. To specify a metal flange guard, provide the flange standard and a drawing or measured dimensions of the connection in its assembled condition.

Information to Provide What It Helps Establish
Flange Standard, Nominal Size and Pressure Designation The flange series and dimensional reference
Flange Outside Diameter The required band diameter and fit around the connection
Assembled Connection Width The band width and intended coverage area
Bolt and Nut Projections Potential interference with the band, tabs or closure
Pipe Outside Diameter and Nearby Obstructions Space available for positioning, opening and removing the guard
Front and Side Photographs Installation details that may not appear on a standard flange drawing

For American, German, Japanese or other flange standards, identify the exact standard rather than the country alone. Where the drawing differs from the installed connection, provide the actual measurements for review.


Application Review for Process Piping

Project inquiries include flange protection for chemical processing plants, pharmaceutical facilities and power-plant piping. Steam and molten-salt duties require the process medium and operating conditions to be identified before a guard configuration is selected.

For valve installations, specify each flanged connection separately and show the valve body, handle or actuator in the photographs. A band fitted around one flange does not provide a complete enclosure for the valve body or operating mechanism.

For spray-shield applications: state the required protective performance and any testing requirements in the inquiry. An external metal band must not be assumed to provide validated pressure diffusion, mist suppression or sealed containment. Any internal mesh or additional protective construction must be explicitly included in the agreed specification.


Installation and Inspection

Have authorized personnel fit the guard under the site's safe-work procedures, including isolation, depressurization and cooling where required. Do not approach an active leak to install or adjust a cover.

Check the guard against the connection drawing, open the band and position it around the specified flange assembly. Verify clearance around the bolts and surrounding equipment before engaging the latch. The band should not be forced into position or distorted to compensate for an incorrect size.

During scheduled maintenance, inspect the band, tabs and closure for damage, deformation or corrosion before considering reuse. Maintain any inspection, drainage or venting provisions required by the approved installation.

This product is an external guard, not a pressure-retaining repair clamp. It does not repair a failed gasket, damaged flange or defective bolted connection.


Frequently Asked Questions

What is the difference between a band-type guard and a full-enclosure flange cover?

A band-type guard surrounds the outside perimeter of the flange assembly and leaves the sides open. A full-enclosure design adds annular side panels around the pipe openings. The two constructions have different coverage geometries and should be selected according to the installation requirements.

Can one guard fit every flange with the same nominal pipe size?

Do not assume interchangeability. The flange standard, pressure designation, outside diameter and assembled width must be checked. Send the actual connection dimensions when requesting a quotation.

Does the flange pressure class define the guard's pressure rating?

No. The flange pressure designation identifies the piping connection. It does not establish the protective performance of an external guard. Any required spray-shield testing must be specified separately for the complete guard configuration.

Does this band-type flange guard provide thermal insulation?

The metal band construction described here is not a removable insulation jacket. For heat retention and insulated valve coverage, see our removable valve insulation covers. Specify thermal insulation and spray protection as separate requirements.

What should be included in an inquiry for stainless steel flange spray shields?

Provide the flange drawing, process medium, normal and maximum operating conditions, required coverage and performance criteria. Identify any internal construction, inspection records or testing documentation required by the project so that the proposed assembly can be reviewed before purchase.


Request a Quotation for Custom Stainless Steel Flange Guards

Send BSTFLEX your flange standard, size, pressure designation, measured dimensions, preferred material grade and required quantity. Include photographs or drawings showing the available installation space, together with the process medium, temperature and pressure using clearly stated units.

For projects covering multiple connections, provide a flange schedule with a separate identification number for each size or installation type. Include your required delivery date and any purchasing, inspection or documentation requirements.

Request a stainless steel band-type flange guard quotation or email your drawings and specifications to sales@pkfiresleeve.com.


Send A Message

If you have questions or suggestions, please leave us a message,we will reply you as soon as we can!

related products
Multi-Layer Stainless Steel Mesh Flange Guards
BSTFLEX Multi-Layer Stainless Steel Mesh Flange Guards combine an external metal band with an internal layered mesh insert for spray-protection requirements at industrial flanged connections. The mesh is positioned around the joint to interrupt a concentrated leak jet, while the removable closure provides access during planned maintenance. Guard dimensions, stainless steel grade and mesh construction are specified against the flange geometry and service conditions. Send your flange standard, dimensions, process medium, operating temperature, pressure and quantity for a project quotation. Protective performance and any required testing must be confirmed for the complete assembly.
Acrylic Coated Fiberglass Welding Blanket
The Acrylic Coated Fiberglass Welding Blanket offers medium-duty protection against sparks, spatter, and abrasion in industrial environments. With a melt temperature of 1000°F (537°C), this fire-resistant blanket is ideal for welding applications, providing excellent shielding on vertical surfaces. Its acrylic coating enhances resistance to water, most chemicals, and wear while ensuring high visibility for safety. Designed primarily for protecting surfaces and personnel, this blanket is not recommended for stress relief but is essential for safeguarding equipment and maintaining safety standards in metalworking, automotive repair, and fabrication industries.
Gold Exhaust Heat Wrap
Gold exhaust heat wrap looks really cool. On a side note, there are also some performance and safety benefits; the degree of insulation afforded by heat wrap keeps exhaust gases hotter in your exhaust system.
Heat Reflective Aluminum Fiberglass Tape
Aluminium Foil Fiberglass Tape is made of glass fiber and aluminium foil. This heat reflective tape has outstanding reflectivity to the heat . Protects from radiant heat by reflecting 90% of the heat that contacts its surface. The aluminum layers will not delaminate from the glassfiber, even under the most extreme heat conditions. 
High Temperature Insulation HTG Fiberglass Sleeve
High Temperature Insulation HTG Fiberglass Sleeve made by E glass fibre and it is widly used in the electrical industry for insulating wires and appliances.
Stainless Steel Exhaust Heat Shields
Stainless Steel Exhaust Heat Shields Pad allows you to customize your exhaust, body or engine bay to protect from unwanted heat ruining your ride or valuable aftermarket components.
Stainless Steel Locking Ties
Stainless Steel Exhaust Wrap Locking Ties are perfect for securing wrap to pipes with its self-locking design. Locking ties offer many other uses including bundling wires, hoses and other forms of insulation products. 
Forklift Fire blanket
In industrial settings where forklifts are the lifeline of operations, the risk of fire poses a substantial threat. Our Forklift Fire Blanket stands as a pioneering solution, ensuring swift and efficient control over forklift fires, be it in electric lithium-powered, fossil fuel, or pallet trucks.
leave a message

leave a message

    If you have questions or suggestions, please leave us a message,we will reply you as soon as we can!

Home

Products

About

Contact

top