item no.:
SIT-SLorder(moq):
200m each sizePayment:
CIF, FOB, EXWproduct origin:
CHINAColor:
Whiteshipping port:
Shanghai, NingboBSTFLEX woven fiberglass insulation tape is a narrow textile made from texturized glass fiber yarn. It is supplied for industrial pipe lagging, equipment joint insulation and protective wrapping. The flexible strip can follow accessible pipework and be cut to the lengths needed for equipment assembly or maintenance.
Specify the tape around the installation: the surface being insulated, available clearance, heat exposure and method of fixing. For a pipe wrap, width and overlap determine coverage. For a flat equipment joint, the contact area and installed thickness are the starting points.
The standard range is white fiberglass tape with a nominal thickness of 1.5 mm. The sizes below are supplied in 30 m rolls. Other widths, thicknesses, lengths and packaging can be requested for quotation.
| Part number | Width | Roll length |
|---|---|---|
| FGT-25 | 25 mm | 30 m |
| FGT-38 | 38 mm | 30 m |
| FGT-50 | 50 mm | 30 m |
| FGT-75 | 75 mm | 30 m |
| FGT-100 | 100 mm | 30 m |
| FGT-125 | 125 mm | 30 m |
| FGT-150 | 150 mm | 30 m |
| FGT-200 | 200 mm | 30 m |
An adhesive-backed version can also be requested. State the backing requirement when ordering; the adhesive type and its service conditions must be considered separately from the fiberglass textile. Minimum order quantity is confirmed with the selected specification.
Fiberglass lagging tape provides a strip-format option for wrapping industrial pipes and narrow sections of equipment. Describe the pipe diameter, length to be covered and surrounding space so that tape width and layer build-up can be selected together. Do not assume a single wrap replaces the full insulation system specified for the installation.
For oven, boiler and other equipment joints designed to accept a textile strip, provide the joint drawing, contact width and required installed thickness. The tape should be selected as part of the joint design; it is not a pressure-retaining pipe repair or a substitute for a specified pressure gasket.
Where industrial hoses or cables require an external thermal wrap, identify the heat source, component temperature limit and access for installation. Include vibration, movement and maintenance requirements in the enquiry. Wrapping does not increase the original temperature rating of the hose or cable itself.
For spiral wrapping, plan the overlap and number of layers before calculating material quantity. Keep coverage consistent around bends and transitions, and secure the ends with fixings suitable for the equipment and operating temperature. Fixings must not cut into or damage the underlying component.
Provide both normal operating conditions and short-duration temperature peaks. Include direct surface contact, surrounding hot air, radiant heat and any exposure to moisture or process chemicals. Request the applicable service data for the selected tape construction when a project has defined temperature or testing requirements.
No. Woven tape provides a continuous strip, while fiberglass ladder tape has an open center section for fixing bolts. Choose the construction around the joint and fastening arrangement rather than treating the two forms as interchangeable.
For a sealing joint where conformability and compression are important, compare the woven construction with knitted fiberglass gasket tape . Evaluate the fit in the actual joint, including its closure force and installed thickness, before specifying a replacement.
Yes. A backing adhesive introduces a separate limit for bonding and installation. Identify whether it is needed only to position the tape or to maintain a bond during service. A fiberglass temperature rating should not be used as the adhesive's rating.
Compare other materials and constructions in the industrial high temperature tapes range .
Send the required width, thickness, roll or cut length, quantity and application. Add the operating temperatures, fixing method and any adhesive-backing requirement. For equipment production or repeat maintenance supply, include a drawing, sample reference or existing specification so the quotation can identify the intended construction.
Img


If you have questions or suggestions, please leave us a message,we will reply you as soon as we can!